This will save half the cost of replacing the entire assembly. Weilmclain peg 5 series operating instructions manualzz. They contain pressurized gas that provides smoother movement and makes them less prone to wear than coiled metal springs. Gas springs and dampers springs grainger industrial supply. The automatic gas vent damper could fail, and if the blocked vent switch does not activate, the vent could leak carbon monoxide co. Gas springs and dampers open and close doors, hatches, access panels, and other objects at steady, controlled speeds. If pilot fails to light, pilot gas and spark off 100% shutoff. In absence of local building codes, installation must comply with nfgc in the united states and the nscngpic in canada. The healthy home system air treatment reference guide features the industrys most complete line of iaq products and solutions. Free instant download get damper opening for gas fireplace. Dampers meet international standards for rectangular and round ducts. After 5 minute delay, a new trial for ignition is initiated.
Weil mclain automatic vent damper with molex connector, 24v, for boiler models cg, eg, cgx, cga, egh, pfg. Before installing, read all instructions, including this supplement, the boiler manual and any related documents. Effikal rvgpks 6 bkf damper control huge inventory. Effikal rvgpksfseries flue damper troubleshooting guide 18. The recall involves effikal rvgppc gas vent damper size 4, 5, 6, 7, 8, 9, or 10 which are installed with the gas boiler systems. Peg30 thru 65 eg30 thru 75 gas fired boilers series 4 control supplement standing pilot. Click here to register to take advantage of our full site capabilities, and access your custom pricing to view columbia pipe list prices, please scroll to the bottom of this page. Ertas 3 tested pocket damper seals for multiple clearance ratios, rotor surface speeds and pressure differentials but only for zero inlet preswirl. It allows you to replace a defective motor without replacing an entire unit. If initially installed and powered up with damper attached, unit must always have a vent damper. Sfds are a means to stabilize aircraft engine rotordynamics due to aerodynamic loads from gas sealing elements.
Field formerly effikal vent damper motor rvgp ks ebay. B fan control gas pressure switch 46506800 c gsk3 spillage switch kit 46086400 d tca1 thermocouple adapter fv model 46082700 d tca2 left hand thread fg model 46429900. Gas cg section and base assembly series 1 through 12 5 11 2 3 1 12 4 9 8 6 8b 10 10a 22 discontinued service parts 7 gas cg section and base assembly series 1. Gas vent dampers recalled by effikal due to carbon monoxide hazard. View and download williamsonthermoflo rvgp users information manual online. Included in the guide are specifications on media filters, uv air purifiers, procell technology, and fresh air controls, plus wiring diagrams, installation options, and replacement parts. A damper installed in this manner will then be free to float with the wallfloor cavity and thermal expansion will not impair operation of the damper. Vent damper motor operator vent damper assemble, 7 johnson q35gh2 vent damper assemble, 8 effikal rvgpks8bkf vent damper assemble, 8 johnson q35gk2 vent damper assemble, 9 effikal rvgpks9bkf vent damper assemble, 9 johnson q35gm2 11b8 11b81703 combination transformerrelay receptacle, 12024 v, 40va white rodgers 5999001. Cpsc recall remedy notice due to covid19 due to the extraordinary circumstances surrounding covid19, some of the remedies identified in recall press releases may not be available at this time. Cas6 oil or gas cas7 oil or gas flue sentinel chimney fan with damper. Eg30 thru 75 peg30 thru 65 for additional information, refer to. This is the only motor made for effikal vent dampers. Weil mclain gas vent damper model rvgpks5bkf 510512345.
Weil mclain automatic vent damper with molex connector, 24v, for. Cg section and base assembly series 1 through 12 manualzz. Field controls gvd5pl 5 automatic vent damper for 24v. The damper has four wires going into our penco boiler. Gas vent dampers recalled by effikal due to carbon monoxide. The flue damper motor is wired separately at terminals 1 and 4.
Field controls technical support information, product brochures and more. Gas vent dampers recalled by effikal due to carbon monoxide hazard important. Halton fdb2 fire dampers are typeapproved class a0a60 fire and gas dampers for use in offshore, marine and navy ventilation systems. Weilmclain peg30 thru 65 you have come to the right place. Combustion air damper damper is factory installed in the aluminized steel burner box extension of the heat exchanger. Engine qualification requires dampers to operate with a full loss of lubricant over a short period of time, typically 30 s, due to a malfunction or under a sudden 0 g maneuver load.
When it proves open, it completes the 24v circuit to the gas valve through terminals 2 and 3. Crocheting, embroidery, knitting, quilting, sewing search for damper opening for gas fireplace basically, anyone who. Vent damper failed can i override to get us through. All dampers have been independently tested and have third party certification. Oct 10, 2000 the flue damper motor is wired separately at terminals 1 and 4.
Installation must comply with regulations of serving gas supplier and local building, heating, plumbing or other codes in effect in the area in which installation is made. Field controls 46491600 vent damper motor assembly plastic base this field controls. Discover classes, experts, and inspiration to bring your ideas to life. Gas piping and electrical inlet knockouts are provided in both sides of the cabinet. Effikal recalls gas vent dampers due to carbon monoxide hazard. Gas vent dampers recalled by effikal due to carbon.
Control dampers are designed for installation in any position with the blades horizontal. If the blades are vertically mounted, then thrust washers are. Energy saving damper closes off combustion air flow through. Weilmclain 510512337 automatic vent damper motor operator, 24v weil mclain automatic vent damper motor operator with molex connector, 24v, for boiler models cg, eg, cgx, cga, egh, pfg. Merv media air cleaner with upgradable procell kit. Continuation proposal to the tamu turbomachinery research. Gas boiler vent damper troubleshooting video youtube. The best damper opening for gas fireplace free download pdf and video. Tim smith from hudson valley community colleges details the entire process troubleshooting a vent damper. Field controls 46491600 vent damper motor assembly gvdrma.
Field controls gas vent damper wiring harness kit ebay. When equipped with effikal vent damper model rvgp, place service switch in hold. Field controls 46491600 vent damper motor assembly plastic base this field controls replacement motor with plastic base takes only a few minutes to install. Item 1 on detail 1 deals with the issue of providing sealant around the retaining angles at. Gvd a motor assembly plastic base 46491600 ovd vent damper motor.
Control of dampers we would like to thank bengt carlson, energy management consultant, the primary contributor to this book, along with larry felker, area sales manager, and robert balkun, product manager, for their efforts in creating this application guide. Damper manufacturers by convention use width by height when placing orders. Venturi propane gas only includes items, 150, and 240. Field controls gvd5pl 5 automatic vent damper for 24v gas systems does not include wiring harness powersports gas tank vents. Return air entry is possible on either or bottom of cabinet. Weil mclain gas vent damper model rvgpks5bkf 510512. B fan control gas pressure switch 46506800 c gsk3 spillage switch kit 46086400 d tca1 thermocouple adapter fv model 46082700 d tca2 left hand thread fg model 46429900 model ck21 millivolt instantaneous gas fired water heater control kit ref. As shown in the drawing at the right, the damper can be turned over so the actuator is on the left or right side. The following boiler models must have damper installed.
Consumer product safety commission, has announced a. All fire dampers have a fusible link and they prevent the spread of fire and gases within the ventilation ductwork. Is there an easy way to override the damper so we can have some heat to get us through the night. Dynamic characterization of fully partitioned damper seals. Weilmclain 5991795 wiring harness for auto vent damper motor wiring harness to connect automatic vent damper motor operator to ignitionsensing control module, with molex connectors.
S8610u3009 universal intermittent pilot gas ignition control. This system is used on gasfired boilers without vent dampers as shipped from the. Ok, time to replace the motor, not the damper itself as it pretty much cant fail. Any other vent damper installed could cause severe personal injury or death. Control dampers are usually installed with the blades horizontal, so the width is the dimension in line with the blades. Weil mclain parts catalog cd version 2010 valve pipe.
Damper assemblies larger than one section are not designed to be structurally selfsupporting. Damper sizes are generally called out using height by width on plans or schedules. This sequence continues until lightoff or call for heat is removed. Multiple appliance controls for use with fan in a can cas control kits. Gvd4 through 12 field controls gvd gas vent damper was developed to reduce off cycle venting losses through boilers and draft hoods. All natural draft boilers will have a spill switch and a flame rollout switch. The damper has a fire resistance rating of ei 60 ve i os, ei 60 ho i os. Weilmclain 381800477 vent damper assembly with harness. Eg30 thru 75 series 4 and peg30 thru 65 series 4 please read this page. Common venting with flue vent damper installation instructions for use by heating contractor common venting with flue vent damper for vitocrossal 200 cm2 series equipped with vitotronic 300 gw5bgw6b product may not be exactly as shown read and save these instructions. Gas tight shutoff damper utg utg applications halton utg dampers are used to shutoff and balance airflow rates in high pressure ductworks. System and boiler by pass free download as pdf file. Intact firefire gas damper fire class ei 60s size 100 630 mm low pressure drop option to regulate flow according to en662 circular damper to prevent the spread of fire and fire gas.